RDNK
Housing:
Orange ABS, Resin Encapsulated
Contacts:
2NO + 1NC (with door open)
Contact Rating:
500mA 24VDC
Coding:
Uniquely Coded, RFID
Indication:
Bi-Colour LED (Open/Close Indication)
Ingress Protection Rating:
IP67 and IP69K
RDNK are standalone, non-contact RFID safety switches. With 2NO + 1NC contacts, capable of switching 500mA at 24Vdc. With tamper proof RFID switching, the RDNK are suitable for use with safety relays with a low inrush current. A dual colour, built in LED helps the operator in speedy fault diagnosis. The RDNK safety switches are available with 3, 6 or 10 metre pre-wired cables which are fully sealed and suitable for use in most wet / harsh environments.
Nazwa | Numer referencyjny | Cena |
---|---|---|
RDNK-21-DC-03M | 364.080 | - |
RDNK-21-DC-06M | 364.081 | - |
RDNK-21-DC-10M | 364.082 | - |
RDNK-ACT | 364.095 | - |
Specyfikacja techniczna | |
Opcje napięcia zasilania | 24Vdc |
Pobór mocy | 2VA / 2W |
Wyjście bezpieczne | 2 X NO |
Ocena wyjścia bezpieczeństwa | 24Vdc / 500mA |
Wyjście AUX | 1 X NC |
Ocena wyjścia AUX | 24Vdc / 500mA |
Przewód/złącze | Okablowany |
Długość przewodu | 3, 6 lub 10 metrów |
Kodowanie | RFID, UNIQUELY CODED |
Wskazanie | DUAL COLOUR LED |
Wymiary przełącznika (mm) | 28 X 52 X 18 |
Wymiary siłownika (mm) | 28 X 52 X 18 |
Masa | NA |
Klasa IP | IP67 / IP69K |
Budowa | Orange ABS, RESIN FILLED |
Montaż | 4 x Śruby zabezpieczające M4 |
Parametry środowiskowe | |
Temperatura robocza | -25°C to +60°C |
Temperatura przechowywania | -10°C to +60°C |
Dane dotyczące bezpieczeństwa | |
PL zgodnie z EN ISO 13849-1 | E |
SIL CL zgodnie z EN IEC 62061 | 3 |
PFHd zgodnie z EN IEC 62061 | 4.3 x 10-8 |
PFH | 6.52 x 10-8 |
B10d | 2,000,000 |
MTTFd | > 100 lat (w oparciu o wskaźnik wykorzystania 360 dni) |
TM | > 20 lat |
DC | 99% |
SFF | 99% |
Notes | |
1) Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years |