RDNK LQD
Housing:
Orange ABS, Resin Encapsulated
Contacts:
2NO + 1NC (with door open)
Connection:
M12, 8-Pole
Coding:
Uniquely Coded, RFID
Indication:
Bi-Colour LED (Open/Close Indication)
Ingress Protection Rating:
IP67 and (IP69K: Pre-Wired Only)
RDNK are standalone, non-contact RFID safety switches. With 2NO + 1NC contacts, capable of switching 500mA at 24Vdc. With tamper proof RFID switching, the RDNK are suitable for use with safety relays with a low inrush current. A dual colour, built in LED helps the operator in speedy fault diagnosis. The RDNK safety switches are available with an M12 leaded quick disconnect which are fully sealed and suitable for use in most wet / harsh environments.
Nazwa | Numer referencyjny | Cena |
---|---|---|
8-CORE-1KEYWAY-05M-QD | 356.073 | - |
8-CORE-1KEYWAY-10M-QD | 356.077 | - |
RDNK-21-DC-LQD | 364.085 | - |
RDNK-21-DC-LQD-05M | 364.083 | - |
RDNK-21-DC-LQD-10M | 364.084 | - |
RDNK-ACT | 364.095 | - |
Specyfikacja techniczna | |
Opcje napięcia zasilania | 24Vdc |
Pobór mocy | 2VA / 2W |
Wyjście bezpieczne | 2 X NO |
Ocena wyjścia bezpieczeństwa | 24Vdc / 500mA |
Wyjście AUX | 1 X NC |
Ocena wyjścia AUX | 24Vdc / 500mA |
Przewód/złącze | Okablowany |
Długość przewodu | 3, 6 lub 10 metrów |
Kodowanie | RFID, UNIQUELY CODED |
Wskazanie | DUAL COLOUR LED |
Wymiary przełącznika (mm) | 28 X 52 X 18 |
Wymiary siłownika (mm) | 28 X 52 X 18 |
Masa | NA |
Klasa IP | IP67 |
Budowa | Orange ABS, RESIN FILLED |
Montaż | 4 x Śruby zabezpieczające M4 |
Parametry środowiskowe | |
Temperatura robocza | -25°C to +60°C |
Temperatura przechowywania | -10°C to +60°C |
Dane dotyczące bezpieczeństwa | |
PL zgodnie z EN ISO 13849-1 | E |
SIL CL zgodnie z EN IEC 62061 | 3 |
PFHd zgodnie z EN IEC 62061 | 4.3 x 10-8 |
PFH | 6.52 x 10-8 |
B10d | 2,000,000 |
MTTFd | > 100 lat (w oparciu o wskaźnik wykorzystania 360 dni) |
TM | > 20 lat |
DC | 99% |
SFF | 99% |
Notes | |
1) Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years |