CET1-AR-CRA-AH-50F-SG safety switch
Stock levels are indicative. If the ordered goods are not in stock, we will inform you about the current delivery date.
Free delivery
from 1000 PLN (net)
Ask an experienced consultant:
CET1-AR-CRA-AH-50F-SG safety switch Euchner
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6,500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Teach-in input
- Escape release, 75 mm long
- Approach direction A (delivery state)
CET1-AR-CRA-AH-50F-SG przełącznik bezpieczeństwa Euchner
Work area
Repeat accuracy R according to EN 60947-5-2 | 10 % |
Electrical connection ratings
Current consumption | |
ICM | 450 mA |
IB | 80 mA |
Fusing | |
external (operating voltage UB) | 0.25 ... 8 A |
external (operating voltage UCM) | 0.5 ... 8 A |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED1, LED2 | 24 V DC -15% V DC ... +10% V DC |
EMC protection requirements | according to EN IEC 60947-5-3 |
Power consumption | |
Solenoid | 11 W |
Safety class | |
EN IEC 61140 | III |
Solenoid duty cycle | 100 % |
Utilization category | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple < 5%, PELV |
Switching load | |
according to UL | 24V DC, Class 2 |
Test pulses | max. 1 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Teach-in input J | |
Input voltage | |
HIGH | 15 ... 27.6 V DC Teach-in input J |
LOW | 0 ... 1 V DC Teach-in input J |
Monitoring output OUT | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0.8xUB ... UB V DC |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Extension of risk time according to EN 60947-5-3 | max. 5 ms |
Discrepancy time | |
both safety outputs | max. 10 ms |
Off-state current Ir | max. 0.25 mA |
Output current | |
per safety output | 1 ... 200 mA |
Output voltage | |
LOW U(OA,OB) | 0 ... 1 V DC |
HIGH U(OA,OB) | UB-1.5V ... UB V DC |
Risk time according to EN 60947-5-3 | |
Single device | max. 400 ms |
Turn-on time | |
Safety outputs | 400 ms |
Mechanical values and environment
Ambient temperature | |
at UB = 24V DC | -20 ... +55 °C |
Approach speed | max. 20 m/min |
Connection | 2 plug connectors M12, 5- and 8-pin |
Degree of protection | IP67 |
Guard locking principle | Closed-circuit current principle |
Installation orientation | any |
Locking force Fmax | 6500 N |
Material | |
Ramp | stainless steel |
Safety switch housing | Die-cast aluminum |
Mechanical life | 2 x 10⁶ |
Ready delay | 10 s |
Degree of freedom X | ±5 mm |
Degree of freedom Y | ±5 mm |
Degree of freedom Z | ±4 mm |
Switching frequency | max. 0.5 Hz |
Shock and vibration resistance | according to EN 60947-5-3 |
Locking force FZh | 5000 N |