CET1-AR-CRA-AH-50F-SG safety switch
Stany magazynowe są orientacyjne. W przypadku braku zamówionego towaru na magazynie poinformujemy o aktualnym terminie realizacji.
Darmowa dostawa
od 1000 PLN (netto)
CET1-AR-CRA-AH-50F-SG safety switch Euchner
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6,500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Teach-in input
- Escape release, 75 mm long
- Approach direction A (delivery state)
CET1-AR-CRA-AH-50F-SG przełącznik bezpieczeństwa Euchner
Work area
Repeat accuracy R according to EN 60947-5-2 | 10 % |
Electrical connection ratings
Current consumption | |
ICM | 450 mA |
IB | 80 mA |
Fusing | |
external (operating voltage UB) | 0.25 ... 8 A |
external (operating voltage UCM) | 0.5 ... 8 A |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED1, LED2 | 24 V DC -15% V DC ... +10% V DC |
EMC protection requirements | according to EN IEC 60947-5-3 |
Power consumption | |
Solenoid | 11 W |
Safety class | |
EN IEC 61140 | III |
Solenoid duty cycle | 100 % |
Utilization category | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple < 5%, PELV |
Switching load | |
according to UL | 24V DC, Class 2 |
Test pulses | max. 1 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Teach-in input J | |
Input voltage | |
HIGH | 15 ... 27.6 V DC Teach-in input J |
LOW | 0 ... 1 V DC Teach-in input J |
Monitoring output OUT | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0.8xUB ... UB V DC |
Safety outputs OA / OB | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Extension of risk time according to EN 60947-5-3 | max. 5 ms |
Discrepancy time | |
both safety outputs | max. 10 ms |
Off-state current Ir | max. 0.25 mA |
Output current | |
per safety output | 1 ... 200 mA |
Output voltage | |
LOW U(OA,OB) | 0 ... 1 V DC |
HIGH U(OA,OB) | UB-1.5V ... UB V DC |
Risk time according to EN 60947-5-3 | |
Single device | max. 400 ms |
Turn-on time | |
Safety outputs | 400 ms |
Mechanical values and environment
Ambient temperature | |
at UB = 24V DC | -20 ... +55 °C |
Approach speed | max. 20 m/min |
Connection | 2 plug connectors M12, 5- and 8-pin |
Degree of protection | IP67 |
Guard locking principle | Closed-circuit current principle |
Installation orientation | any |
Locking force Fmax | 6500 N |
Material | |
Ramp | stainless steel |
Safety switch housing | Die-cast aluminum |
Mechanical life | 2 x 10⁶ |
Ready delay | 10 s |
Degree of freedom X | ±5 mm |
Degree of freedom Y | ±5 mm |
Degree of freedom Z | ±4 mm |
Switching frequency | max. 0.5 Hz |
Shock and vibration resistance | according to EN 60947-5-3 |
Locking force FZh | 5000 N |