GIGA4005B2PO/SIL2/US
- For ensuring machine safety
- Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849
- No special actuator for electronic fail-safe sensors required
- Connection to safety PLC, safe AS-i modules or safe evaluation units
Technical data
Product characteristics | |||||||||||||||||||
Electrical design | PNP | ||||||||||||||||||
Output function | 2 x OSSD (A1 and A2) | ||||||||||||||||||
Enable zone [mm] | &rt; 10 | ||||||||||||||||||
Housing | threaded type | ||||||||||||||||||
Dimensions [mm] | M18 x 1 / L = 86.5 | ||||||||||||||||||
Application | |||||||||||||||||||
Special feature | Gold-plated contacts | ||||||||||||||||||
Type of operation | continuous operation (maintenance-free) | ||||||||||||||||||
Safety-related function | safe state when damped correctly | ||||||||||||||||||
Application | industrial application | ||||||||||||||||||
Electrical data | |||||||||||||||||||
Operating voltage [V] | 10...30 DC | ||||||||||||||||||
Rated insulation voltage [V] | 30 | ||||||||||||||||||
Current consumption [mA] | < 30 | ||||||||||||||||||
Protection class | III | ||||||||||||||||||
Reverse polarity protection | yes | ||||||||||||||||||
Max. power-on delay time [ms] | 1000 | ||||||||||||||||||
Outputs | |||||||||||||||||||
Electrical design | PNP | ||||||||||||||||||
Output function | 2 x OSSD (A1 and A2) | ||||||||||||||||||
Max. voltage drop switching output DC [V] | 2.5; (30 mA) | ||||||||||||||||||
Minimum load current [mA] | 2 | ||||||||||||||||||
Permanent current rating of switching output DC [mA] | 50 | ||||||||||||||||||
Output data | Interface type C class 1 | ||||||||||||||||||
Output voltage at 24 V | compatible with EN 61131-2 inputs type 1, 2 | ||||||||||||||||||
Short-circuit protection | yes | ||||||||||||||||||
Max. capacitive load CL_max [nF] | 20 | ||||||||||||||||||
Detection zone | |||||||||||||||||||
Enable zone [mm] | &rt; 10 | ||||||||||||||||||
Safe switching-off distance s(ar) [mm] | < 5 | ||||||||||||||||||
Response times | |||||||||||||||||||
Response time to safety request [ms] | 5 | ||||||||||||||||||
Response time when approaching the enable zone [ms] | 5 | ||||||||||||||||||
Risk time (response time for safety-related faults) [ms] | 45 | ||||||||||||||||||
Operating conditions | |||||||||||||||||||
Applications | class C to EN 60654-1 weatherproof application | ||||||||||||||||||
Ambient temperature [°C] | -25...70 | ||||||||||||||||||
Note on ambient temperature |
|
||||||||||||||||||
Ambient temperature [°C] | 10...40 | ||||||||||||||||||
Note on ambient temperature |
|
||||||||||||||||||
Rate of temperature change [K/min] | 0.5 | ||||||||||||||||||
Max. relative air humidity [%] | briefly: 5...95 %; permanent: 5...70 % | ||||||||||||||||||
Air pressure [kPa] | 80...106 | ||||||||||||||||||
Max. height above sea level [m] | 2000 | ||||||||||||||||||
Ionising radiation | not permissible | ||||||||||||||||||
Salt spray | IEC 60068-2-11 | ||||||||||||||||||
Protection | IP 65; IP 67 | ||||||||||||||||||
Tests / approvals | |||||||||||||||||||
EMC |
|
||||||||||||||||||
Shock resistance |
|
||||||||||||||||||
Vibration resistance |
|
||||||||||||||||||
Safety classification | |||||||||||||||||||
Complies with the requirements |
|
||||||||||||||||||
Mission time TM [h] | ≤ 175200 | ||||||||||||||||||
Mission time TM (additional indication) |
|
||||||||||||||||||
PFH [1/h] | < 1,0E-07 | ||||||||||||||||||
Mechanical data | |||||||||||||||||||
Weight [g] | 163.5 | ||||||||||||||||||
Housing | threaded type | ||||||||||||||||||
Mounting | flush mountable | ||||||||||||||||||
Dimensions [mm] | M18 x 1 / L = 86.5 | ||||||||||||||||||
Thread designation | M18 x 1 | ||||||||||||||||||
Materials | brass white bronze coated; PBT | ||||||||||||||||||
Displays / operating elements | |||||||||||||||||||
Display |
|
||||||||||||||||||
Accessories | |||||||||||||||||||
Items supplied |
|
||||||||||||||||||
Remarks | |||||||||||||||||||
Remarks |
|
||||||||||||||||||
Pack quantity | 1 pcs. | ||||||||||||||||||
Electrical connection - plug | |||||||||||||||||||
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |